XXDP+ SUPERVISOR | HSAA |
When you load one of this newer diagnostics control goes first to the supervisor portion, which will identify himself :
DIAG. RUN-TIME SERVICES REV D APR-79
CZRLI-C-0 (writes the test and REV to be run)
CZRLI TESTS THE RL01-02 INTERFACE AND BASIC ...
UNIT IS RL01-RL02
DR>
Valid commands are :
STA/FLAGS: start test initially RES/PASS: restart after ^C (back to pass 0) CON/TESTS: continue where stopped after a ^C PRO/FLAGS: proceed after a error halt DRO/UNITS: drop unit from testing ADD/UNITS: add unit for testing PRI print all statistic tables accumulated DIS/UNITS: the hardware P-tables are printed FLA the current flag-settings are printed ZFL all flags are clearedThe flags are:
HOE halt on error, causing command mode LOE loop on error, causing diagnostic to loop IER inhibit error reporting IBE inhibit basic error reports IXE inhibit extended error reports PRI direct all messages to the line printer PNT print number of test being executed BOE bell on error UAM run in unattended mode, bypass manual intervention ISR inhibit statistical reports IDU inhibit dropping of units by diagnostics