11/34       EIS TEST FKAC

ABSTRACT :
This program tests the ASH, ASHC, MUL, DIV instructions.

In the memory locations 404 is a 16 bit pass count.
This test can be power failed with no error.

HARDWARE REQUIREMENTS :
The test needs 4k of memory.

OPERATING PROCEDURES :
.R FKAC??         (200 normal start)
222 restart to save the pass count.

The program does not print any title.
After testing it prints "END PASS".

ERROR REPORTING :
The format is as follows :
     ADR        ERRNM

  ADR    = address of error
  ERRNM  = error number
			
In most cases the comment beside the call for halt subroutine tells what was being checked and what was expected.

SWITCH SETTINGS :
  SW 15  = 1   halt on error
  SW 13  = 1   inhibit error type outs
			
If no hardware switch register is available, the program automatically uses the contents of location 176 as the software switch register.

close this window